background

Server: Dell R730xd with H330 RAID Controller Storage: 2x800G SSD configured in RAID 1 Requirement: Migrate the SSDs to a new server while maintaining the RAID 1 configuration and preserving data integrity

将SSD迁移至新的服务器,并保证RAID配置、数据不变

Steps

To migrate RAID 1 configuration from the Dell R730xd with the H330 RAID controller to a new server, you can follow these steps:

从Dell R730xd服务器迁移RAID 1配置,可以按照以下的步骤进行

Prepare the new server: Ensure the new server has a compatible RAID controller

确保新服务器的RAID控制器适配,一般同一品牌的RAID控制器都能够适配

Shut down the old server: Power off the R730xd server containing the RAID 1 configuration.

关闭旧服务器

Connect the disks to the new server: Remove the two SSDs configured in the RAID 1 array from the old server. Install the two disks into the new server’s RAID controller.

将两块硬盘插到新的服务器中,位置、顺序可以不一样。

Import the foreign configuration: When you power on the new server, the RAID controller will detect the existing RAID 1 configuration as a “foreign” configuration. You can then import this configuration into the new RAID controller. You can do this through the PERC BIOS configuration utility by selecting “Import Foreign Configuration”.

  • Press <F> to automatically import the foreign configuration.
  • Enter the BIOS Configuration Utility and navigate to the Foreign Configuration View.

新服务器开机,进入到RAID控制器中,会出现一个选择"Import Foreign Configuration",导入外部配置,就可以将旧的RAID配置导入。

Verify the RAID 1 configuration: After importing the foreign configuration, ensure the RAID 1 array is properly recognized and functioning on the new server.

导入配置以后,确到RAID 1 阵列被正确的识别。到这一步,所有的工作就全部完成了!


Refs

Migrating virtual disks